GA-DCP004 - 96-Well SEQ Dye Clean up kit
Product details
Product number GA-DCP004
Product name 96-Well SEQ Dye Clean up kit
Quantity 4plates/kit
Supplier Gentaur

96-Well SEQ Dye

Clean Up Kit

Sample: 10-50 µl sequencing reaction product

Operation time: 15-20 min.

Elution volume: 10-50 µl

Store at room temperature (15 - 25°C )

For research used only

Introduction

Avegene 96-Well SEQ Dye Clean Up Kit is designed for high-throughput

purification of DNA sequencing reactions. Ultra filtration (UF) membrane is

used to separate extremely small particles and dissolved molecules based

on their size. Salts and unincorporated dye terminators could be effectively

removed from reaction mixture without alcohol precipitation or gel filtration.

The kits are compatible with ABI Prism BigDye, Beckman CEQ or

Amersham DYEnamic ET Dye Terminator chemistres and can be used for

manual filtration or with robotic handing systems. The entire procedure can

be completed in 20 minutes.

Quality Control

The quality of 96-Well SEQ Dye Clean Up Kit is tested on a lot-to-lot basis.

The Kits are tested by deterrmining the presence of contamination signals

in sequencing electropherogram.

Kit Contents

Name GA-DCP02 GA-DCP04 GA-DCP10

Dye Wash Buffer 50 ml 100 ml 250 ml

96-Well Dye remove plate 2 plate 4 plate 10 plate

0.35ml collection plate 2 plate 4 plate 10 plate

Adhesive Film 2 pcs 4 pcs 10 pcs

 

Additional Required

1. Multi-Well Plate Vacuum Manifold

2. Loading Buffer

Caution

Buffer contains irritant agent. During operation, always wear a lab coat,

disposable gloves, and protective goggles.

 

Vacuum Protocol

1. Add 2X volume of Dye Wash Buffer to sequencing reaction

product. (If your product volume less then 20 µl, adjust final

volume to 20 µl with water). Mix gently by pipetting several times.

2. Place the Dye Remove Plate on the vacuum manifold.

3. Transfer diluted sample from Step 1 into the bottom of each well.

4. Set the vacuum to 25" Hg and turn on the vacuum pressure for 5-10

minutes until each well was empty.

5. Turn off the vacuum.

6. Add 100 µl Dye Wash buffer to each well on the plate.

7. Turn on the vacuum pressure for 5-10 minutes or until each well was

empty.

8. Turn off the vacuum and remove the plate from the manifold.

9. Press the plate on an absorbent material (tissue paper) to blot out the

excess liquid from the bottom of the plate.

10. Place the Dye Remove Plate on the vacuum manifold and turn on the

vacuum pressure for 5 minutes.

11. Add 20-30 µl of sequencing loading buffer or deionized water

into central of the membrane. Pipet up and down 5-10 times to elute

the sequencing product.

12. Transfer eluted products to a new 96 well 0.35ml collection plate.

Centrifuge Protocol

1. Add 2X volume of Dye Wash Buffer to sequencing reaction

product. (If your product volume less then 20 µl, adjust final

volume to 20 µl with water). Mix gently by pipetting several times.

2. Place the Dye Remove Plate on the waste collection plate( not

provide ).

3. Transfer diluted sample from Step 1 into the bottom of each well.

4. Centrifuge for 5 min at 3,500 rpm in a centrifuge.

5. Add 100 µl Dye Wash buffer to each well on the plate.

6. Centrifuge for 20 min at 3,500 rpm in a centrifuge.

7. Add 20-30 µl of sequencing loading buffer or deionized water into

central of the membrane. Pipet up and down 5-10 times to elute the

sequencing product.

8. Transfer eluted products to a new 96 well 0.35ml collection plate.

 

Material Safety Data Sheet

1

96-Well SEQ Dye Clean Up Kit

Authorization date: 1/1/2006 Revision date: 1/1/2006

Print Date: 10/4/2006 Version: 1

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY

/ UNDERTAKING

Commercial Product name: 96-Well SEQ Dye Clean Up Kit

Product number: GA-DCP02, GA-DCP04, GADCP10

Intended use: Biochemical kit

Supplier: Pacific Image Electronics Co., Ltd.

10F-1, No. 81, Hsin Tai Wu Rd., Sec. 1,

Hsi Chih, Taipei, Taiwan 221

Emergency telephone number: +886 2 2698 0369

2. CHEMICAL CHARACTERISATION

Component 1:

Dye wash buffer: 1 Piece (s)

Ingredients 1-2.5% sodium Dodecyl sulfate; CASNo.

00151-21-3

3. HAZARDS IDENTIFICALTION

******************** EMERGENCY OVERVIEW **************

Component 1 – Occupational exposure presents little or no health

hazard.

*******************************************************

Potential Health Effects:

Eye: Can cause moderate irritation, tearing and reddening, but not

likely to permanently injure eye tissue. Can cause severe

irritation. Eye contact may result in corneal injury. Symptoms

may include discomfort or pain, excess blinking and tear

production, with marked redness and swelling of the

conjunctiva. Temporary vision impairment (cloudy or blurred

vision) is possible.

Skin: Can cause moderate skin irritation, defatting, and dermatitis.

Material Safety Data Sheet

2

Not likely to cause permanent damage. May cause allergic

skin reaction.

Inhalation: Can cause minor respiratory irritation, dizziness,

weakness, fatigue, nausea, and headache. Can be

corrosive to the respiratory tract causing severe irritation

and tissue damage. If liquid mists are breathed into the

lungs, they may be rapidly absorbed through the lungs

and injure specific target organs. No toxicity expected

from inhalation.

Ingestion: Mildly irritating to mouth, throat, and stomach. Can cause

abdominal discomfort. Harmful if swallowed. May cause

systemic poisoning. Corrosive to tissue. Can cause severe

and permanent damage to mouth, throat, and stomach.

Aspiration may lead to lung damage. Ingestion of this

product may result in central nervous system effects

including headache, sleepiness, dizziness, slurred speech

and blurred vision. Harmful if swallowed. May cause

systemic poisoning.

Chronic: No data on cancer. Contains a substance(s) that is a

possible reproductive system hazard based on high dose

tests with laboratory animals.

4. FIRST AID MEASURES

Eye: Flush eyes with plenty of water for at least 20 minutes

retracting eyelids often. Tilt the head to prevent chemical from

transferring to the uncontaminated eye. Remove contact

lenses, clean before re-use. Get immediate medical attention.

Skin: Wash with soap and water. Remove contaminated clothing

and launder immediately, and discard contaminated leather

goods, and wash before re-use. Get medical attention

immediately if irritation develops or persists.

Inhalation: Remove to fresh air. If breathing is difficult, have a

trained individual administer oxygen. If not breathing,

give artificial respiration and have a trained individual

administer oxygen. Get medical attention immediately.

Ingestion: Complent 1 – Give plenty of water, if conscious. If

Material Safety Data Sheet

3

vomiting occurs naturally, wash mouth out. Be

prepared to induce vomiting upon a physician's advice.

Obtain medical attention if symptoms develop.

Note To Physician: Treat symptomatically.

5. FIRE FIGHTING MEASURE

Flashpoint Deg C: Not available.

Upper Flammable Limit %: Not available.

Lower Flammable Limit %: Not available.

Autoignition Temperature Deg C: Not available.

Extinguishing Media: Complent 1, 4 and 5 – Use means

appropriate for surrounding materials.

Firefighting Techniques/Equipment: Do not enter fire area without

proper protection including selfcontained

breathing apparatus

and full protective equipment.

Fight fire from a safe distance

and a protected location due to

the potential of hazardous

vapors and decomposition

products.

Hazardous Combustion Products: Includes carbon dioxide, carbon

monoxide, and dense smoke.

6. ACCIDENTAL RELEASE MEASURES

Accidental releases may be subject to special reporting

requirements and other regulatory mandates. Refer to Section 8 for

personal protection equipment recommendations.

Spill Cleanup: Complent 1, 4 and 5 – Absorb spill. Common

absorbent materials should be effective. Deposit in

appropriate containers for removal and disposal.

Material Safety Data Sheet

4

7. HANDLING AND STORAGE

Storage of some materials is regulated by federal, state, and/or

local laws.

Storage Pressure: Ambient

Handling Procedures: Complent 1 – Keep closed or covered when

not in use.

Storage Procedures: Suitable for most general chemical storage

areas.

8. EXPOSURE CONTROLS, PERSONAL PROTECTION

Exposure Limits:

Component OSHA PEL (ppm) AGCIH TWA (ppm)

SODIUM DODECYL SULFATE Not established. Not established.

GUANIDINE HCL Not established. Not established.

Engineering Controls: Local exhaust ventilation or other engineering

controls are normally required when

handling or using this product to avoid

overexposure.

Personal Protective Equipment:

Eye: An eye wash station must be available where this product is

used. Wear chemical goggles.

Skin: Avoid skin contact by wearing chemically resistant gloves, an

apron and other protective equipment depending upon

conditions of use. Inspect gloves for chemical break-through

and replace at regular intervals. Clean protective equipment

regularly. Wash hands and other exposed areas with mild soap

and water before eating, drinking, and when leaving work.

Have a safety shower available.

Respiratory: A respiratory protection program that meets OSHA's

29 CFR 1910.134 and ANSI Z88.2 requirements must

be followed whenever workplace conditions warrant a

respirator's use.

Material Safety Data Sheet

5

9. PHYSICAL AND CHEMICAL PROPERTIES

Appearance/physical state: Liquid solution / suspension

Order: No odor.

Specific Gravity/Density: Not established.

Octanol/water Partition Coeff: Not established.

Volatiles: Not established.

Evaporation Rate: Not established.

Viscosity: Not established.

Infection: No Infection

10. STABILITY AND REACTIVITY

Stability: Stable under normal conditions.

Conditions to Avoid: Strong oxidizing agents. High temperatures.

Strong acids.

Hazardous Decomposition Products: None known.

Hazardous Polymerization: Hazardous polymerization will not occur.

11. TOXICOLOGICAL INFORMATION

Acute Toxicity (Rat):

Dermal/Skin: Sodium Dodecyl Sulfate: Dermal LD50 >10 G/KG

Inhalation/Respiratory: GUANIDINE: 475 MG/KG 3250 MG/KG

Oral/Ingestion: Sodium dodecyl sulfate: Oral LD50 = 1288 MG/KG

Target Organs: Kidneys. Central Nervous System.

Carcinogenicity:

NTP: Not tested.

IARC: Not listed.

OSHA: Not regulated.

Other Toxicological Information

Contains a substance(s) that is a possible reproductive system

hazard based on high dose tests with laboratory animals.

12. Ecological Information

Material Safety Data Sheet

6

Ecotoxicological Information: No ecological information available.

Environmental Fate (Degradation,

Transformation, and Persistence):

Bioconcentration is not expected to

occur.

13. DISPOSAL CONSIDERATIONS

Regulatory Information: Not applicable.

Disposal Method: Clean up and dispose of waste in accordance with

all federal, state, and or local environmental.

14. TRANSPORT INFORMATION

NOT RESTRICTED ACCORDING TO IATA REGULATION.

Proper Shipping Name: Not Determined.

Subsidiary Hazards:-

15. OTHER INFORMATION

WHMIS Rating 0-4:

FIRE:0.

HEALTH: 2.

REACTIVITY: 0

Abbreviations

N/A - Data is not applicable or not available

SARA - Superfund and Reauthorization Act

HMIS - Hazard Material Information System

WHMIS - Workplace Hazard Materials Information System

NTP - National Toxicology Program

OSHA - Occupational Health and Safety Administration

IARC - International Agency for Research on Cancer

PROP 65 - California Safe Drinking Water and Toxic Enforcement Act

of 1986

EINECS - European Inventory of Existing Commercial

Chemical Substances

 

 

 

 

Price
EUR408
USD510
GBP327
DKK3.040
JPY67.139
PLZ1.391
SEK3.813
NOK3.238
Buy or request info
 
Selected products

Europe - Gentaur Molecular Products bvba, Av. de l' Arme 68, B-1040 Brussels Tel:  +32 2 732 56 88 Fax. : +32 2 732 44 14
France 9, rue Lagrange 75005 Paris Tel:  01 43 25 01 50 Fax:  01 43 25 01 60
Italy Tel:  02 36 00 65 93 Fax: 02 36 00 65 94
Japan, Minaatojimaminami-manchi, Chuo-ku, Kobe 065-0047 Tel: +81 78 386 0860Fax: +81 78 306 0296